(@oafpatroll)
Posts: 1106
Noble Member
 

That refrigerant stuff, gas or what, fill it myself or what ?

I doubt you can as you need special fittings and probably couldn't easily buy it. Any refridgeration company could do it for you. If I had the room I'd do it once it was refurbed for peace of mind or if it wasn't easily maintaing temp. I have no need whatever for a cold room but Fr some twisted reason I have the jealousies.


 
Posted : 01/11/2024 10:25 am
(@treeman)
Posts: 1767
Noble Member
Topic starter
 

What is this gauge ?
What does this do - how is it read, interpreted.
It seems to be between a pump and a canister.

20241102_124857 by David Frank Allen, on Flickr


I am who I am - I am not who you want me to be.
Therefore I am me.

 
Posted : 02/11/2024 8:07 am
 Ds J
(@ds-j)
Posts: 330
Reputable Member
 

If memory serves correct, it measures the pressure in the gas unit (activated by heat/cold) to switch the pump/fan on and off.


 
Posted : 02/11/2024 9:20 am
(@jamesnotbond)
Posts: 101
Estimable Member
 

Dave, those are pressure controller gauges, yours being dual gauges. You can monitor your operating pressures so as for the pumps not to overwork. These will also indicate if there is some fault in your cooling system.
They can be set, but I have only ever used a technician to do so.

Note to self: Its time to learn the ability to set operating pressures, it cannot be too complicated.


 
Posted : 02/11/2024 10:13 am
(@newton)
Posts: 511
Honorable Member
 

Dave, those are pressure controller gauges, yours being dual gauges.
You can monitor your operating pressures so as for the pumps not to overwork. These will also indicate if there is some fault in your cooling system.
They can be set, but I have only ever used a technician to do so.

How much pressure is in the refrigerant bottle ?
and
In the corroded fittings ?


 
Posted : 02/11/2024 10:42 am
(@treeman)
Posts: 1767
Noble Member
Topic starter
 

How much pressure is in the refrigerant bottle ?
and
In the corroded fittings ?

************************
Zoom in, looks like 40 PSI and like 300 otherside


I am who I am - I am not who you want me to be.
Therefore I am me.

 
Posted : 02/11/2024 12:27 pm
 Ds J
(@ds-j)
Posts: 330
Reputable Member
 

Suggestion: please get a competent technician and pay him to do a thorough inspection of the whole unit. Then get another competent technician to affirm the findings of the first one.

Pay him some more to show you to how to adjust it, and please listen if he tells you not to adjust anything 😉 (I didn't listen and it almost cost a lot of money).

The systems change all the time; if it is old or not well supported,  try to start saving for a new one. It will probably break down on a Saturday afternoon when you are returning on Sunday with an extra carcass 😉


 
Posted : 02/11/2024 1:35 pm